Prediction of mechanical loosening in cemented acetabular cups by the immediate postoperative radiograph

Main Article Content

German Garabano
Fernando Lopreite
Harold Simesen de Bielke
Agustin Oviedo
Gabriel Nazur
gustavo Gomez Rodrigues
Hernan del Sel

Abstract

IntroductionThe durability of prosthetic components in total hip arthroplasty (THA) is one of the main topics of discussion. In the evaluation of the acetabular mechanical loosening (AML) come into play several aspects, including the hardened. A retrospective analysis was performed to predict the AML, analyzing the quality of the cemented in immediate radiography (Rx) postoperative (PO), comparing it to the radiographic findings in the medium and long term. Method180 cemented THA, with an average of 7.7 years follow-up and an average age of 66 years were analyzed. Interface bone-cement of each cup were analyzed, comparing the immediate PO Rx with the ultimate control, settling a score for boundaries observed in each area of Lee Charnley, capable of identifying and evaluating the AML.ResultsOf the 180 THA, 149 cups were considered well fixed (83%) and 31 badly fixed (17%). The radiographic AML averaged was 12.7% (23 of 180 hips). The median follow-up was 7.7 years. In the initially well set, there were 20 cases of radiographic AML (11.1%), without need for revision surgery. The wrong set cups had a percentage of AML clinical and radiographic 19,35% (6/31). ConclusionWe consider that a correct cemented technique decreases the likelihood of radiographic AML and improve long term clinical survival. While longer term follow-up and a greater number of patients are necessary, we believe that the quality of the cement interdigitation, in the immediate PO Rx is predictive of future AMA. 

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Article Details

How to Cite
Garabano, G., Lopreite, F., Simesen de Bielke, H., Oviedo, A., Nazur, G., Gomez Rodrigues, gustavo, & del Sel, H. (2012). Prediction of mechanical loosening in cemented acetabular cups by the immediate postoperative radiograph. Revista De La Asociación Argentina De Ortopedia Y Traumatología, 77(2), 118-123. https://doi.org/10.15417/85
Section
Clinical Research

References

1. Kavanagh BF, Dewitz MA, Ilstrup DM, Stauffer RN, Coventry MB. Charnley total hip arthroplasty whith cement. J Bone Joint Surg 1989;71A:1496-503.

2. Mc Coy TH, Salvati EA, Ranawat CS, Wilson Jr PD. A fifteen-year follow-up study of one hundred Charnley low friction arthroplasties. Orthop Clin North Am 1998;19:467-6.

3. Eftekhar NS, Nercessan O. Incidence and mechanism of failure of cemented acetabular component in total hip arthroplasty. Orthop Clin North Am 1986;19:557-66.

4. Garcia-Cimbrelo E, Munuera L. Early and late loosening of the acetabular cup after low friction arthroplasty. J Bone Joint Surg 1992;74A:1119-29.

5. Brand RA, Yoder SA, Pedersen DR. Interoserver variability in interpreting radiographic lucencies about total hip reconstructions. Clin Orthop Relat Res 1985;192:237-9.

6. Carlsson AS, Gentz CF. Mechanical loosening of the femoral head prosthesis in the charnley total hip arthroplasty. Clin Orthop Relat Res 1983;147:262-70.

7. Carlsson AS, Gentz CF, Sanzen L. Socket loosening after hip arthroplasty. Acta Orthop Scand 1986;57:97-100.

8. Charnley J. Acrylic cement in orthopaedic surgery. Edinburgo: Livingstone; 1970. p. 24-60.

9. Charnley J. Low friction arthroplasty of the hip. Berlín: Springer-Verlag; 1979. p. 78-87.

10. Goetz DD, Smith EJ, Harris WH. The prevalence of femoral osteolysis associated with components inserted with or without cement in total hip replacements. J Bone Joint Surg Am 1994;76:1121-29.

11. Gruen TA, McNeice GM, Amstutz HC. “Modes of failure” of cemented stem-type femoral components. A radiographic analysis of loosening. Clin Orthop Relat Res 1979;141:17-27.

12. Mjöberg B. Loosening of the cemented hip prosthesis. Acta Orthop Scand 1986;221:5-40.

13. Ranawat CS, Deshmukh RG, Peters LE. Prediction of long term durability of all polyethylene cemented sockets. Clin Orthop Related Res 1995;317:89-105.
14. Salvati, EA, Freiberger RH. And Wilson PD. Artrography for complications of total hip replacement. J Bone Joint Surg 1971; 53A:701-9.

15. Ranawat C, Deshmukh, RG, et al. Prediction of long-term durability of all-polyethylene cemented sockets. Clin Orthop Related Res 1995;317:89-105.

16. Mjöberg B. The theory of early loosening of hip prostheses. Orthopedics 1997;20:1169-70.

17. Clohisy JC, Harris WH. Matched-Pair analysis of cemented and cementless acetabular reconstruction in primary total hip arthroplasty. J Arthroplasty 2001;16-6:697-704.

18. De Lee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Related Res 1976;121:20-32.

19. McCaskie AW, Brown AR, Thompson JR. Radiological evaluation of the interfaces after cemented total hip replacement. J Bone Joint Surg Br 1996;78B:191-4.

Most read articles by the same author(s)