Comparative study with high-flex total knee arthroplasty. functional and range of motion results

Main Article Content

Matías Costa Paz

Abstract

AbstractBackground: The purpose of this comparative study is to analyze functional results and the range of motion of the knee between two groups of patients with total knee arthroplasty using high-flex prosthesis (in one group) and with a conventional implant (in the other).Methods: Sixty-four patients were surgically treated with total knee arthroplasty with Zimmer NexGen®, USA. From this series, 22 patients (group A) were treated with high-flex design. Two cases with rheumatoid arthritis were excluded. Forty-two patients were treated with a conventional implant, 21 of them were excluded, and group B included 21 patients. Maximum flexion and extension were evaluated before and after surgery. Functional evaluation was performed with the Knee Society Score (KSS), the Western Ontario and McMaster Universities osteoarthritis index (WOMAC), and an analogous visual scale.Results: The mean pre-surgical maximum flexion was 99° in group A and 106º in group B. Mean post-surgical maximum flexion in group A increased to 114º with an average increase of 15º and, in group B, to 118º with an average gain of 12º. There were no significant statistical differences (p <0.05). Pre-surgical KSS in group A was 36/48 and increased to 90/92. In group B, pre-surgical KSS was 46/49 and 94/90 after surgery.Conclusion: This study suggests that there are no significant differences in the range of motion, functional results, and radiographic evaluation in a high-flex total knee arthroplasty and a conventional design after one year of follow-up. 

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Article Details

How to Cite
Costa Paz, M. (2014). Comparative study with high-flex total knee arthroplasty. functional and range of motion results. Revista De La Asociación Argentina De Ortopedia Y Traumatología, 79(3), 142-148. https://doi.org/10.15417/197
Section
Clinical Research
Author Biography

Matías Costa Paz, Hospital Italiano de Buenos Aires

Jefe Int. del Sector de Artroscopia y Protesis de Rodilla

References

1. Bin SI, Nam TS. Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery. Knee Surg Sports
Traumatol Arthrosc 2007;15:350-5.

2. Coughlin KM, Incavo SJ, Doohen RR, Gamada K, Banks S, Beynnon BD. Kneeling kinematics after total knee arthroplasty:
anterior-posterior contact position of a standard and a high-flex tibial insert design. J Arthroplasty 2007;22:160-5.

3. Huang HT, Su JY, Wang GJ. The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up.
J Arthroplasty 2005;20:674 9.

4. Huddleston JI, Scarborough DM, Goldvasser D, Freiberg A, Malchou H. How often do patients with high-Flex total knee
arthroplasty use high flexion? Clin Orthop Relat Res 2009;467:1898-906.

5. Kim YH, Sohn KS, Kim JS. Range of motion of standard and high-flexion posterior stabilized total knee prostheses: a
prospective, randomized study. J Bone Joint Surg Am 2005;87:1470-5.

6. Kim YH, Choi Y, Oh-Ryong K, Kim JS. Functional outcome and range of motion of high-flexion posterior cruciate-retaining
and high-flexion posterior cruciate substituting total knee prostheses. A prospective, randomized study. J Bone Joint Surg Am
2009;91:753-60.

7. Laskin RS. The effect of a high-flex implant on postoperative flexion after primary total knee arthroplasty. Orthopedics 2007;30
(Suppl):86-8.

8. McCalden RW, MacDonald SJ, Bourne RB, Marr JT. A randomized controlled trial comparing “high-flex” vs “standard”
posterior cruciate substituting polyethylene tibial inserts in total knee arthroplasty. J Arthroplasty 2009;24(Suppl):33-8.

9. Mehin R, Burnett RS, Brasher PMA. Does the new generation of high-flex knee prostheses improve the post-operative range of
movement? A meta-analysis. J Bone Joint Surg Br 2010;92:1429-34.

10. Ng FY, Wong HL, Yau WP, Chiu KY, Tang WM. Comparison of range of motion after standard and high-flexion posterior
stabilised total knee replacement. Int Orthop 2008;32:795-8.

11. Weeden SH, Schmidt R. A randomized, prospective study of primary total knee components designed for increased flexion.
J Arthroplasty 2007;22:349-52.

12. Ritter MA, Harty LD, Davis KE, Meding JB, Berend ME. Predicting range of motion after total knee arthroplasty. J Bone
Joint Surg Am 2003;85:1278-85.

13. Nutton RW, van der Linden ML, Rowe PJ, Gaston P, Wade FA. A prospective randomised double-blind study of functional
outcome and range of flexion following total knee replacement with the NexGen standard and high flexion components. J Bone
Joint Surg Br 2008;90:37-42.

14. Seon JK, Park SJ, Lee KB, Yoon TR, Kozanek M, Song EK. Range of motion in total knee arthroplasty: a prospective
comparison of high-flexion and standard cruciate-retaining designs. J Bone Joint Surg Am 2009;91:672-9.

15. Wohlrab D, Ditl J, Herrschelmann R, Schietsch U, Hein W, Hube R. Does the NexGen LPS flex mobile knee prosthesis
offer advantages compared to the NexGen LPS?: a comparison of clinical and radiological results. Z Orthop Ihre Grenzgeb
2005;143:567-72.