Fractura por fatiga de un tallo de revisión femoral modular cónico estriado de fijación distal.

Contenido principal del artículo

Martin Buttaro
Douglas Van Citters
Evan Carlson
Fernando Comba
Pablo Slullitel
Francisco Piccaluga

Resumen

1. Engelbrecht E, Heinert K. Klassifikation und Behandlungsrichtlinien von Knochensubsanzverlusten bei Revisionsoperationen am Huftgelenk mittelfrsige Ergebnisse. Primare und Revisionsalloarthroplastik Hrsg-Endo-Klinik, Hamburg: Springer-Verlag, Berlin; 1987:189.2. Merle d’Aubigné R, Postel M. Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am 1954;36:451.3. Hood RW, Wright TM, Burstein AH. Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses. J Biomed Mat Res 1983;17:829.4. Carlsson AS, Gentz CF, Stenport J. Fracture of the femoral prosthesis in total hip replacement according to Charnley. Acta Orthop Scand 1977;48:650-5.5. Chao EYS, Coventry MB. Fracture of the femoral component after total hip replacement. An analysis of fifty-eight cases. J Bone Joint Surg Am 1981;63:1078-94.6. Charnley J. Fracture of femoral prostheses in total hip replacement. A clinical study. Clin Orthop 1975;111:105.7. Buttaro M, Mayor M, Van Citters D, Piccaluga F. Fracture of a proximally modular, distally fluted uncemented implant with diaphyseal fixation. J Arthroplasty 2007;22(5):780-3.8. Bohm P, Bischel O. Femoral revision with the Wagner SL revision stem: evaluation of one hundred and twenty-nine revisions followed for a mean of 4.8 years. J Bone Joint Surg Am 2001;83(7):1023.9. Woolson ST, Milbauer JP, Bobyn JD, Yue S, Maloney WJ. Fatigue fracture of a forged cobalt-chromium-molybdenum femoral component inserted with cement. A report of ten cases. J Bone Joint Surg Am 1997;79(12):1842.

Descargas

Métricas

Vistas del PDF
57
Jul 2013Jan 2014Jul 2014Jan 2015Jul 2015Jan 2016Jul 2016Jan 2017Jul 2017Jan 2018Jul 2018Jan 2019Jul 2019Jan 2020Jul 2020Jan 2021Jul 2021Jan 2022Jul 2022Jan 2023Jul 2023Jan 2024Jul 2024Jan 2025Jul 2025Jan 20267.0
|

Detalles del artículo

Cómo citar
Buttaro, M., Van Citters, D., Carlson, E., Comba, F., Slullitel, P., & Piccaluga, F. (2013). Fractura por fatiga de un tallo de revisión femoral modular cónico estriado de fijación distal. Revista De La Asociación Argentina De Ortopedia Y Traumatología, 77(4), 260-263. https://doi.org/10.15417/133
Sección
Presentación de casos
Biografía del autor/a

Martin Buttaro, Centro de Cadera Hospital Italiano de Buenos Aires

Medico de planta, Centro de Cadera "Sir John Charnley"Servicio de Ortopedia y Traumatología "Carlos E. Ottolenghi"Hospital Italiano de Buenos Aires